The PF2100F
Flare Ignition System
- Intuitive and clear
- programming menus
- 12V or 24V operation supported
- low power
- On Demand or Fixed Interval spark option using:
- Flame Detection
- Thermocouple
- Ionization
- Optional Modbus RS485 communication
- Optional High Temperature Shutdown
- Pilot solenoid control
- Programmable set-points for Alarm and Temperature
- Designed and tested to operate over a wide range of ambient temperatures (-40°C to +65°C)
- Class 1 Division 2, NEMA 4X enclosure
- See overview description below for details regarding additional zoning capability
Get A Quote Share Product
Applications
- Flare Pits
- Flare Stacks
Class 1, Division 2, Grp ABCD; T4A
CSA Type 4X
CSA C22.2 No. 0-M91
CSA C22.2 No. 0.4-04
CSA C22.2 No. 94-91
CSA C22.2 No. 142-M1987
CSA C22.2 No. 213-M1987
CSA E60730-1:02
CSA E60079-0:2007
CSA E60079-1
Power Supply Requirements | VALUE | |
---|---|---|
Base Model | 12/24 VDC | |
Power Consumption | 12VDC | 24VDC |
Controller Only (Display On) | 2.6 W | 2.9 W |
Controller Only (Display Off) | 1.1 W | 1.2 W |
Max Total Current Draw | 5 A | 5 A |
Max Valve Current Draw | 2 A | 2 A |
Ignition Voltage (Internal Coil) | Up to 20kV | Up to 40kV |
Temperature Ratings | Min | Max |
Operating Range | -40°C (-40°F) | +55°C (+130°F) |
Storage Range | -40°C (-40°F) | +80°C (+176°F) |
Terminal Blocks | VALUE | |
Maximum Wire Gauge | 12 AWG | |
Status Contact | VALUE | |
Type | Dry | |
Max Voltage | 40 VDC | |
Max Continuous Current | 250 mA | |
Impedance (When Closed) | 15? | |
Physical Dimensions | VALUE | |
Width | 30.9 cm (12.15 in) | |
Height | 23.4 cm (9.23 in) | |
Depth | 13.4 cm (5.28 in) | |
Weight | VALUE | |
Base Model | 4.0 lbs (1.8kg) | |
Base Model Plus 1 Expansion Card | 4.5 lbs (2.0 kg) | |
Base Model Plus 2 Expansion Cards | 6.0 lbs (2.6 kg) |