PF2100
Natural Draft Burner Management
We set the standard for advanced burner management
Proven Reliability
With over 60,000 in operation, the PF2100 has become the standard in Burner Management Systems for natural draft applications.

Ultra Fast
Intuitive Interface and user experience

Integrated
High temperature shutdown, Temperature control, History and event log, 4-20 output

Expansion
Modbus RS485, 4-20 Input Tank level and Fuel gas pressure, Data Logging

Low Power Design

Solar and TEG ready, Low cost of ownership

The Class Leader
The PF2100 is an advanced Burner Management System capable of managing a wide array of natural-draft burner applications, including:
- Combustors
- Gas Production Units
- Treaters
- Tank Heaters
- Amine & Glycol Reboilers
- Heated Separators
- Emulsion Treaters
- Heater Treaters
- Condensate Stabilizers

Applications
- Amine & Glycol Reboilers
- Combustors
- Condensate Stabilizers
- Dehydrators
- Emulsion Treaters
- Gas Production Units
- Heated Separators
- Heater Treaters
- Incinerators
- Line Heaters
- Tank Heaters
Class 1 Division 2, Group A, B, C, and D; T4A, Type 4X
Ex nA IIC T4 IP66
Class 1, Zone 2, AEx nA IIC T4 IP66
ANSI Z21.20
ANSI-ISA-12.12.01-2007
CSA 22.2 No. 199
CSA C22.2 No. 213-M1987
CSA C22.2 No. 0-M91
CSA C22.2 No. 0.4-04
CSA C22.2 No. 94-91
CSA C22.2 No. 142-M1987
CSA E60079-0:2007
CSA E60079-15:2005
UL 372
Detailed Specs
POWER REQUIREMENTS
12 VDC*: 1.1 W typical (92mA typical**, 5A max)
24 VDC*: 1.4 W typical (60mA typical**, 5A max)
*System voltage must match valve rating
**Not including valves, display off
TEMPERATURE RATING
-40°C to 55°C (-40°F to 130°F)
INPUTS AND OUTPUTS
1 Ignition Coil Output
1 Flame Detection Input
3 Thermocouple Inputs
6 Dry Contact Inputs for safety interlock device connections
1 Dry Status Contact Output
3 Valve Control Outputs
1 Programmable 4-20mA Output
2 4-20mA Inputs
1 NO/NC Dry Contact Output
STATUS CONTACT RATINGS
Dry, Max 40VDC, Max 250mA continuous
PHYSICAL DIMENSIONS
309 x 234 x 134 mm (12.15" x 9.23" x 5.28")
2.3 kg (5 lbs)
APPROVALS
Class 1 Division 2, Group A, B, C, and D; T4A, Type 4X
Ex nA IIC T4 IP66
Class 1, Zone 2, AEx nA IIC T4 IP66
ANSI Z21.20
ANSI-ISA-12.12.01-2007
CSA 22.2 No. 199
CSA C22.2 No. 213-M1987
CSA C22.2 No. 0-M91
CSA C22.2 No. 0.4-04
CSA C22.2 No. 94-91
CSA C22.2 No. 142-M1987
CSA E60079-0:2007
CSA E60079-15:2005
UL 372

POWER REQUIREMENTS
12 VDC*: 1.1 W typical (92mA typical**, 5A max)
24 VDC*: 1.4 W typical (60mA typical**, 5A max)
*System voltage must match valve rating
**Not including valves, display off
TEMPERATURE RATING
-40°C to 55°C (-40°F to 130°F)
INPUTS AND OUTPUTS
1 Ignition Coil Output
1 Flame Detection Input
3 Thermocouple Inputs
6 Dry Contact Inputs for safety interlock device connections
1 Dry Status Contact Output
3 Valve Control Outputs
1 Programmable 4-20mA Output
2 4-20mA Inputs
1 NO/NC Dry Contact Output
STATUS CONTACT RATINGS
Dry, Max 40VDC, Max 250mA continuous
PHYSICAL DIMENSIONS
309 x 234 x 134 mm (12.15" x 9.23" x 5.28")
2.3 kg (5 lbs)
APPROVALS
Class 1 Division 2, Group A, B, C, and D; T4A, Type 4X
Ex nA IIC T4 IP66
Class 1, Zone 2, AEx nA IIC T4 IP66
ANSI Z21.20
ANSI-ISA-12.12.01-2007
CSA 22.2 No. 199
CSA C22.2 No. 213-M1987
CSA C22.2 No. 0-M91
CSA C22.2 No. 0.4-04
CSA C22.2 No. 94-91
CSA C22.2 No. 142-M1987
CSA E60079-0:2007
CSA E60079-15:2005
UL 372