Pre-packaged solutions for quick procurement
PF3100-QP Control Panels
The PF3100-QP Control Panels are factory-wired burner management panels built on the PF3100 platform for quick procurement. Choose QP24 for single-burner appliances or QP36 for dual-burner appliances.
One Panel. Fully Wired. Designed for Quick Procurement.
-
Factory-installed BMS controller card(s) and UV pilot card(s), pre-wired into the panel
-
Integral power supply and wire marshaling area, so field wiring lands in one place
-
Corrosion-resistant stainless steel enclosure, rated for outdoor field installation
-
Configuration is based on the appliance main valve power (AC or DC) and draft type
Burner Count Decides the Panel
For most applications, burner count is the only decision. Single burner? Choose the PF3100-QP24. Dual burner? The PF3100-QP36 adds a second BMS controller for independent control of each burner.
Two factors that can push to the larger panel:
- I/O Count
- Enclosure Size
What doesn't move the decision:
Identical on both panels
- Draft type
- Application type
- Certifications
- Environmental rating
- Control capability
Meet the Panels
PF3100-QP24
The Single-Burner Panel
Single-burner control for natural or forced draft appliances, in one integrated panel.
- 1 BMS Controller, 1 UV pilot (installed & pre-wired)
- 1 pilot valve, 2 main SSV, 1 HFV/FAN
- 4 configurable inputs, dedicated pressure, level, & flame quality
- 2 x 4-20mA, 2 status relays, 1 ignition enable relay outputs
- UV flame detection
The PF3100-QP24 panel requires a temperature module, mounted at the appliance. Running ionization flame detection instead of UV? You’ll also need the Ion Pilot EPX Module.
PF3100-QP36
The Dual-Burner Panel
Dual-burner control for natural or forced draft appliances, in one integrated panel.
- 2 BMS controller cards, independent safety control of each burner
- 2 UV pilot & 2 I/O expansion cards, 1 Modbus, 1 Network card
- 2 pilot valve outputs, 4 main SSV, & 2 HFV/FAN (both burners run from one cabinet)
- 8 configurable inputs & 4 4-20mA outputs
- 4 status relays, 2 ignition enable relay
- I/O redundancy
- Larger cabinet with more room for installation and service
- Same field modules as the PF3100-QP24
Side by Side
What Each Panel Includes
Each PF3100-QP panel comes fully equipped.
Standard components, inputs, and outputs for each option are listed in the table.
| Attribute | PF3100-QP24 | PF3100-QP36 |
|---|---|---|
| Burners | One | Two |
| BMS Controller Cards | 1 | 2 |
| UV Pilot Cards | 1 | 2 |
| I/O Expansion Cards | 1 | 2 |
| Network Card | Not included | Included |
| Pressure / Level Inputs | 1 | 1 per BMS |
| Configurable Analog/Digital Inputs | 4 | 4 per BMS |
| Flame Quality Analog Inputs | 1 | 1 per BMS |
| Analog Outputs (4-20mA) | 2 | 2 per BMS |
| Discrete Inputs (Aux, Start, ESD, Proof of Closure) | 1 | 1 per BMS |
| Pilot Valve Outputs | 1 | 1 per BMS |
| Main SSV Outputs | 2 | 2 per BMS |
| HFV/FAN Outputs | 1 | 1 per BMS |
| Normally Open Status Relays | 2 | 2 per BMS |
| Ignition Enable Relays | 1 | 1 per BMS |
| I/O Redundancy | Not included | Included |
| Enclosure Size | Smaller | Larger |
Same Platform.
Same Certifications.
Same Support.
The standardization in the QP24 and QP36 is in the packaging, the wiring, and the scope of supply, not in what the platform can do.
-
Platform
Full PF3100 with PID temperature control, UV flame detection, event logging and diagnostics, Modbus, and I/O expansion
-
Enclosure
Stainless steel, IP66 / Type 4X, rated –40°F to 104°F (–40°C to +40°C)
-
Power and display
120VAC input (15A max AC variants, 10A max DC variants), 5.7" color LCD, AC or DC main valves
-
Certifications
BMS controller to UL 60730-2-5 / CSA C22.2 No. 60730-2-5 / ANSI Z21.20, UL 121201 / CSA C22.2 No. 213, and UL508A / CSA C22.2 No. 286; Class I Div 2 Group ABCD, T4; Class I Zone 2 Group IIC (US)
-
Applications
Amine reboiler, combustor / ECD / VDU, gas production unit, glycol dehydrator, heated separator, heated tank, line heater, treater
-
Configuration
By main valve power (AC or DC) and draft type
When Standard Doesn't Fit,
Profire Engineers It
The QP24 and QP36 cover most single- and dual-burner applications. For everything else, Profire offers PF3100-based panels engineered to your requirements.
A Custom Panel Makes Sense When Your Application:
- Operates more than two burners, or multiple pilots
- Needs I/O or ports beyond what the two standard packages support
- Requires shutdown logic that interlocks with plant systems outside a standard sequence
- Has to meet a site standard for enclosure or control architecture
- Needs parallel positioning, fuel/air ratio control, or O2 trim.
Frequently Asked Questions
What's the difference between the PF3100-QP24 and the PF3100-QP36?
Burner count. The QP24 controls one burner; the QP36 controls two, with a second BMS controller card so each burner runs its own independent safety control. Both run the full PF3100 platform, carry the same certifications, and support the same applications.
How do I know which panel my application needs?
Start with burner count. One burner points to the QP24, two burners point to the QP36. If burner count doesn’t settle it, check I/O, and enclosure size. Any of those can push the spec up to the QP36.
Do the QP24 and QP36 support forced draft appliances?
Yes. Both handle natural and forced draft. But only the QP24 can handle forced draft with parallel positioning, fuel/air ratio control, O2 trim, and damper control on single burner appliances. That capability needs to be configured and requires additional customization.
What if my application runs more than two burners?
That’s outside what a standard panel is built for. Profire’s engineered path runs on the same PF3100 platform and is built for applications with more than two burners, multiple pilots, non-standard I/O, or shutdown logic that interlocks with other plant systems.
What certifications do the PF3100-QP24 and PF3100-QP36 carry?
Both are certified as BMS Controllers to UL 60730-2-5 / CSA C22.2 No. 60730-2-5 / ANSI Z21.20, UL 121201 / CSA C22.2 No. 213, and UL508A / CSA C22.2 No. 286, with Class I Div 2 Group ABCD, T4 and Class I Zone 2 Group IIC (US) ratings. Certifications are identical across both panels.
What's pre-installed in the panel versus mounted at the appliance?
The BMS controller card(s), UV pilot card(s), and related I/O hardware are factory-installed and pre-wired inside the panel. The Temperature Module is required at the appliance for either panel to run, and the Ion Pilot EPX Module mounts at the appliance for ionization applications only.