Vertical Heater Treater Burner and Flame Arrestor Upgrade

Installing properly sized burners & flame arrestors on an Oil & Gas E&P Company’s Vertical Heater Treaters ended months of missed production. Tell us more about your project
Vertical heater treater with a Profire PF2150 controller, circular burner housing, and elevated access platform.

Project Highlights

  • Replaced undersized burners & flame arrestor housings
  • PF2150 with HBB Fuel Train packages installed - no vessel modification
  • Packages shipped pre-wired & pre-configured for straightforward installation
  • Vessels reached temperature the same afternoon the equipment went in
  • 15% improvement in fuel gas savings
  • 6 installations completed so far, with more scheduled to come
  • Designed for NFPA 87/ASME & ANSI Z21.21/CSA 6.5

Have Similar Equipment?

Tell us about your next project

Get a Free Quote

The Problem

Despite operating significant upstream positions throughout North and South Texas, several of a Oil & Gas E&P Company’s Vertical Heater Treaters struggled to maintain or even reach temperature, no matter how long their burners operated.

When Profire was called in to assess the situation, we discovered that the cause was mostly mechanical. Each Vertical Heater Treater was operating with a burner management system, but the issue lied within the burner systems themselves. The burners were undersized to the equipment needs, and so were the flame arrestor housings. This meant that these two critical systems were never set up correctly for the Vertical Heater Treaters.

These appliances, Vertical Heater Treaters, are inherently tricky. They don’t provide a burner much room to operate because of their short firetubes, which are only 4-5ft long. A short firetube means less room to control the oxygen contents, if left un-optimized, that makes it difficult for the burner to operate without running out of air. It’s a short flame path for combustion, and it puts a lot of the operating load on the air control systems. When your burner and flame arrestor can’t move enough air through the firetube, the heat never transfers into the vessel. What this meant for the Oil & Gas E&P Company is that their burners were firing continuously, wasting fuel, while the vessels always stayed below temperature, and their sites fell short of their production quotas.

Sound Familiar? Let's Talk

The Profire Solution

The Oil & Gas E&P Company first raised the problem with their local equipment partner, Summit Pump & Safety, who brought us in to determine whether one of our pre-packaged solutions could solve the issue.

To confirm the solution for this Oil & Gas E&P Company our team ventured out to their field locations. After measuring their appliances, we were able to determine and properly size the required burners and flame arrestors for the Vertical Heater Treaters.

With this project, getting the flame arrestor housing right mattered as much as the burner itself, since a restricted housing on a 4ft firetube will starve the burner of air.

To maintain the burner management approach that the company was already operating with, we standardized their systems with PF2150 BMS Controllers combined with an HBB Fuel Train that we shipped pre-wired and pre-configured. These systems ensured the sites carried the same safety and temperature functions their field team operated with and they made installation straightforward.

Our technicians supported the installations alongside Summit Pump & Safety, pulling the undersized equipment off each heater and bolting the new package on in their place. Our team also supported the full system commissioning and post-installation combustion tuning. The initial order covered three packages, two at one site and a third a mile down the road. After monitoring the systems for a month, the Oil & Gas E&P Company felt we had achieved what we set out to do, and the results carried the program forward. We are now at six installations so far, with another three scheduled at the time of publication.

Key elements included:

  • High Efficiency M7 Burners: Selected for the 4ft firetube, without the adjustable secondary airplate.
  • Flameco Flame Arrestors: Ensures proper airflow while keeping the system safe
  • PF2150 BMS Controller: Pilot flame safety & vessel temperature control, and high-temperature shutdown, matching what was already in service.
  • HBB Quick Stand Fuel Train: Designed for up to 4.5MM BTU/hr, paired with the PF2150 BMS

The Results

The first Vertical Heater Treater reached temperature, and maintained it, the same afternoon the new equipment was installed. This Oil & Gas E&P Company had spent months trying to hold temperature in these vessels.

The Vertical Heater Treaters now ramp up quickly, hit setpoint, and cycle the burner off once temperature is achieved. That cycling is where the gas savings come from, up to 15%. Enough air reaches the flame to complete combustion, the heat transfers, and the burner shuts down instead of firing continuously, wasting gas, and still falling short.

The Oil & Gas E&P Company monitored the upgraded units for a month, and the results beat their expectations. The sites are now meeting production after struggling to do so for months and losing out on production.

The systems were also designed with enough margin so that in the winter months the cold weather won’t be a concern for the equipment.

After proving the system can meet and hold temperature without having a technician drive out to work on the appliance, the Oil & Gas E&P Company is now taking the same approach with the Vertical Heater Treaters their operators identify with the same symptoms.

Get a Free Quote

After Profire

Close-up of a burner assembly inside a circular metal housing, showing fuel tubing and ignition wiring.
Profire PF2150 burner management controller beside a circular burner housing, with fuel piping and pressure gauges.
Vertical heater treater with a Profire PF2150 controller, circular burner housing, and elevated access platform.
Open burner enclosure exposing the firetube opening, pilot assembly, and wiring beside an access ladder.
Profire PF2150 controller and fuel train mounted beside an open burner enclosure on a vertical process vessel.
Vertical process vessel with a closed burner enclosure, exhaust stack, fuel piping, and fixed access ladder.

Ready to Optimize your Equipment?

Let Profire help with your Safety, Reliability, and ESG Initiatives

Get a Free Quote

Recent Projects

Vertical Heater Treater… Oil & Gas – Upstream
Details

Despite operating significant upstream positions throughout North and South Texas, several of a Oil & Gas…

See Details
Cabin Heater, Cogen… Oil & Gas – Midstream
Details

Western Midstream operates a natural gas processing plant near Denver, Colorado that had been running for…

See Details
Dual-Tube Horizontal Heater… Oil & Gas – Upstream
Details

A leading Oil & Gas producer operated 148 aging dual-tube horizontal heater treaters running on pneumatic…

See Details